• USA Home
  • T-093 - Delta9-Tetrahydrocannabinolic acid A solution

EMAIL THIS PAGE TO A FRIEND
T-093 Supelco

Delta9-Tetrahydrocannabinolic acid A solution

1.0 mg/mL in acetonitrile, ampule of 1 mL, certified reference material, Cerilliant®

Synonym: THCA-A

  • CAS Number 23978-85-0

  • Empirical Formula (Hill Notation) C22H30O4

  • Molecular Weight 358.47

  •  MDL number MFCD20133805

  •  NACRES NA.24

Purchase

Properties

Related Categories Additional Standards, Analytical Standards, Analytical/Chromatography, Cannabinoids, Cannabis Testing - Cannabinoids,
Quality Level   100
  300
grade   certified reference material
feature   Snap-N-Spike®/Snap-N-Shoot®
packaging   ampule of 1 mL
mfr. no.   Cerilliant®
concentration   1.0 mg/mL in acetonitrile
format   single component solution
shipped in   dry ice
storage temp.   −70°C
InChI   1S/C22H30O4/c1-5-6-7-8-14-12-17-19(20(23)18(14)21(24)25)15-11-13(2)9-10-16(15)22(3,4)26-17/h11-12,15-16,23H,5-10H2,1-4H3,(H,24,25)/t15-,16-/m1/s1
InChI key   UCONUSSAWGCZMV-HZPDHXFCSA-N

Description

General description

Δ9-Tetrahydrocannabinolic acid A (THCA-A) is a non-psychoactive acidic cannabinoid found in Cannabis that reportedly exhibits anti-inflammatory, neuroprotective, and anti-cancer effects. This certified Snap-N-Spike® solution is suitable for THCA-A testing methods by GC/MS, LC/MS or HPLC for applications in clinical toxicology, testing of Cannabis potency or impurity profiling, pharmaceutical research, forensic analysis, and urine drug testing. Cerilliant solution Certified Reference Materials (CRMs) of cannabinoids are supplied in a convenient, quantitative, US DEA-exempt solution format and with TK#s for Canadian customers.

Legal Information

CERILLIANT is a registered trademark of Cerilliant Corporation

Snap-N-Shoot is a registered trademark of Cerilliant Corporation

Snap-N-Spike is a registered trademark of Cerilliant Corporation

Safety & Documentation

Safety Information

Symbol 
Signal word 
Danger
Hazard statements 
Precautionary statements 
RIDADR 
UN 1648 3 / PGII
WGK Germany 
WGK 2
Flash Point(F) 
Not applicable
Flash Point(C) 
Not applicable
Protocols & Articles

Articles

Analysis of Active Cannabis Compounds in Edible Food Products: Gummy Bears and Brownies

Potency testing in marijuana-infused edibles is a problematic task that analytical labs are facing due to the complexity of the involved matrices. Among the most popular matrices are gummy bear candi...
Keywords: High performance liquid chromatography, Sample preparations, Separation

Cannabinoid Standards

Cannabinoids are a class of psychoactive substances that are among the most widely abused and readily available drugs in the world.1,2 These drugs can produce intense psychological and physiological ...
Keywords: Cancer, Clinical, Forensic, Gas chromatography, High performance liquid chromatography, Ion-exchange chromatography, Mass spectrometry, Metabolites

HPLC Analysis of Active Cannabinoid Compounds in Gummy Bear Candy on Ascentis® Express Biphenyl with UV Detection after Extraction

From our library of Articles, Sigma-Aldrich presents HPLC Analysis of Active Cannabinoid Compounds in Gummy Bear Candy on Ascentis® Express Biphenyl with UV Detection after Extraction
Keywords: Chromatography, High performance liquid chromatography, Pharmaceutical

The Definitive Guide to Cannabis Testing

The cannabinoids found in the Cannabis plant, commonly referred to as marijuana, have grown in popularity for treating a variety of ailments from arthritis, glaucoma and chronic pain to malnutrition,...
Keywords: Cancer, Chromatography, Clinical, Controlled substances, Diseases, Forensic, Gas chromatography, Genetic, Ion-exchange chromatography, Metabolites, Pesticides, Solvents

UHPLC (Isocratic) Analysis of 14 Cannabinoids on Ascentis® Express C18

From our library of Articles, Sigma-Aldrich presents UHPLC (Isocratic) Analysis of 14 Cannabinoids on Ascentis® Express C18
Keywords: Clinical, Diseases, Forensic, Gas chromatography, High performance liquid chromatography, Mass spectrometry, Pharmaceutical, Separation

UHPLC (Isocratic) Analysis of 14 Cannabinoids on Chromolith® HR RP-18e

From our library of Articles, Sigma-Aldrich presents UHPLC (Isocratic) Analysis of 14 Cannabinoids on Chromolith® HR RP-18e
Keywords: Clinical, Diseases, Forensic, Gas chromatography, High performance liquid chromatography, Mass spectrometry, Pharmaceutical, Separation

UHPLC Analysis of Cannabinoids on Ascentis Express C18

From our library of Articles, Sigma-Aldrich presents UHPLC Analysis of Cannabinoids on Ascentis Express C18

UHPLC/MS Analysis of Cannabinoids Extracted from Raw Cannabis Sativa (Marijuana) on Ascentis® Express RP-Amide

From our library of Articles, Sigma-Aldrich presents UHPLC/MS Analysis of Cannabinoids Extracted from Raw Cannabis Sativa (Marijuana) on Ascentis® Express RP-Amide
Keywords: Chromatography, Diseases, High performance liquid chromatography, Mass spectrometry, Pharmaceutical, Sample preparations, Separation

UHPLC/MS Analysis of Ten Cannabinoids on Ascentis® Express RP-Amide

From our library of Articles, Sigma-Aldrich presents UHPLC/MS Analysis of Ten Cannabinoids on Ascentis® Express RP-Amide
Keywords: Chromatography, Clinical, Diseases, Forensic, Gas chromatography, High performance liquid chromatography, Mass spectrometry, Pharmaceutical, Separation, Solvents

Related Products

related product

Product #

Description

Add to Cart

C-142 Cannabigerolic acid solution, 1.0 mg/mL in acetonitrile, ampule of 1 mL, certified reference material, Cerilliant®
C-143 Cannabichromene solution, 1.0 mg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®
C-144 Cannabidiolic acid solution, 1.0 mg/mL in acetonitrile, ampule of 1 mL, certified reference material, Cerilliant®
T-093 Delta9-Tetrahydrocannabinolic acid A solution, 1.0 mg/mL in acetonitrile, ampule of 1 mL, certified reference material, Cerilliant®
C-150 Cannabichromenic Acid (CBCA) solution, 1.0 mg/mL in acetonitrile, certified reference material, ampule of 1 mL, Cerilliant®
C-153 Cannabinolic Acid (CBNA) solution, 1.0 mg/mL in acetonitrile, certified reference material, ampule of 1 mL, Cerilliant®
T-111 Tetrahydrocannabivarinic acid (THCVA) solution, 1.0 mg/mL in acetonitrile, certified reference material, ampule of 1 mL, Cerilliant®
C-171 Cannabicyclolic Acid (CBLA) solution, 0.5 mg/mL in acetonitrile, certified reference material, ampule of 1 mL, Cerilliant®
T-145 delta9-Tetrahydrocannabinolic acid A-D3 (THCA-A-D3) solution, 100 μg/mL in acetonitrile, certified reference material, ampule of 1 mL, Cerilliant®
C-217 Hemp Compliance Mix solution, certified reference material, ampule of 1 mL, Cerilliant®
C-219 Cannabinoid Mixture (Neutrals) - 8 Component solution, certified reference material, ampule of 1 mL, Cerilliant®
T-151 THC-O-Acetate solution, 1 mg/mL in methanol, certified reference material, ampule of 1 mL, Cerilliant®
C-220 Cannabinoid Mixture - 3 Component solution, 1 mg/mL in methanol ((each analyte)), certified reference material, ampule of 1 mL, Cerilliant®
C-218 Cannabinoid Mixture (Acids) - 6 Component solution, 500 μg/mL (1% DIPEA and 0.05% Ascorbic acid in Acetonitrile,each analyte), certified reference material, ampule of 1 mL, Cerilliant®
C-244 Cannabichromenic Acid (CBCA) solution, 1 mg/mL (1% DIPEA and 0.05% Ascorbic acid in Acetonitrile), certified reference material, ampule of 1 mL, Cerilliant®
T-093S Delta9-Tetrahydrocannabinolic acid A solution, 1 mg/mL in acetonitrile, certified reference material, ampule of 1 mL, Cerilliant®
C-045 Cannabidiol solution, 1.0 mg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®
C-046 Cannabinol solution, 1.0 mg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®
C-084 Cannabidiol-D3 solution, 100 μg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®
C-115 Cannabinol-D3 solution, 100 μg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®
T-003 (−)-Δ9-THC-D3 solution, 100 μg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®
T-005 (−)-trans-Δ9-THC solution, 1.0 mg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®
T-011 (−)-Δ9-THC-D3 solution, 1.0 mg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®
T-032 (−)-Δ8-THC solution, 1.0 mg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®
T-033 exo-THC solution, 1.0 mg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®
C-140 Cannabidivarin solution, 1.0 mg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®
C-141 Cannabigerol solution, 1.0 mg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®

Technical Service:

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Bulk Ordering & Pricing:

Need larger quantities for your development, manufacturing or research applications?